Difference between revisions of "Cooling Tower (Large)"

From Captain of Industry Wiki
Jump to: navigation, search
(+navbox)
m (Rename "Steam Hi" and "Steam Lo" in recipes to "Steam (High)" and "Steam (Low)")
 
(12 intermediate revisions by 7 users not shown)
Line 2: Line 2:
| Name          = Cooling Tower (Large)
| Name          = Cooling Tower (Large)
| Tier          = 2
| Tier          = 2
| Image        =
| Description  = Improves [[Water]] efficiency of a power plant by recovering some [[Steam]] back to Water.
| Description  = Improves [[Water]] efficiency of a power plant by recovering some [[Steam]] back to Water.
| Recipe        =  
| Recipe        =  
Line 15: Line 14:
| Maintenance  = None
| Maintenance  = None
| Footprint    = 9x9
| Footprint    = 9x9
| Research      = Nuclear Reactor
| BoostByUnity  = yes
| Designation  = Power Production
| Research      = Power Generation IV
| Designation  = Water Extraction & Processing
| Variants      = [[Cooling Tower]]
| Variants      = [[Cooling Tower]]
}}
}}
The '''Cooling Tower (Large)''' is a much higher throughput and physically much larger variant of the [[Cooling Tower]] which allows for the conversion of [[Steam Hi]], [[Steam Lo]], and [[Steam Depleted]] byproducts into [[Water]]. As the ratio of [[Water]] to all types of steam is 1:1, the Cooling Tower (Large) thus recovers 83.3% of the Water contained therein. Compared to the Cooling Tower, this marks a 33% increase in the Water recovery rate.
The '''Cooling Tower (Large)''' is a much higher throughput and physically much larger variant of the [[Cooling Tower]] which allows for the conversion of {{infoicon|Steam (Super)}}, {{infoicon|Steam Hi}}, {{infoicon|Steam Lo}}, and {{infoicon|Steam Depleted}} byproducts into {{infoicon|Water}}. As the ratio of {{infoicon|Water}} to all types of steam is 1:1, the Cooling Tower (Large) thus recovers 75% of the Water contained from {{infoicon|Steam Lo}}, and {{infoicon|Steam Depleted}}. Compared to the regular Cooling Tower, this marks a 50% increase in the Water recovery rate.


While it is designed for use in [[Nuclear Reactor]] setups as its throughput is an exact match, it could theoretically be used to recover water from any steam byproduct. It can process the resulting steam output from up to 24 [[Arc Furnace II]] machines or 6 [[Exhaust Scrubber]]s.
It can process the resulting steam output from up to 16 [[Arc Furnace II]] machines or 4 [[Exhaust Scrubber]]s. Conversely, it takes exactly 3 of these to handle the steam output of a single [[Nuclear Reactor]] with 3x output.
 
{{recipe define
==Recipes==
  | Input1Name  = Steam (Super)
{{Recipe
  | Input1Qty  = 16
   | Input1Name  = Steam Hi
  | Time        = 10
   | Input1Qty  = 48
  | Output1Name = Water
  | Output1Qty  = 8
}}{{recipe define
   | Input1Name  = Steam (High)
   | Input1Qty  = 16
   | Time        = 10
   | Time        = 10
   | Output1Name = Water
   | Output1Name = Water
   | Output1Qty  = 40
   | Output1Qty  = 10
}}
}}{{recipe define
{{Recipe
   | Input1Name  = Steam (Low)
   | Input1Name  = Steam Lo
   | Input1Qty  = 16
   | Input1Qty  = 48
   | Time        = 10
   | Time        = 10
   | Output1Name = Water
   | Output1Name = Water
   | Output1Qty  = 40
   | Output1Qty  = 12
}}
}}{{recipe define
{{Recipe
   | Input1Name  = Steam Depleted
   | Input1Name  = Steam Depleted
   | Input1Qty  = 48
   | Input1Qty  = 16
   | Time        = 10
   | Time        = 10
   | Output1Name = Water
   | Output1Name = Water
   | Output1Qty  = 40
   | Output1Qty  = 12
}}
}}
 
{{Footer Infobox}}
{{Navbox/Machines}}

Latest revision as of 15:50, 16 May 2023

Water Extraction & Processing.png
Cooling Tower (Large)
T2
Cooling Tower (Large).png
Improves Water efficiency of a power plant by recovering some Steam back to Water.
Construction
Construction Parts III.png
80
+
Concrete Slab.png
200
WorkersWorker.png 4
ElectricityNone
MaintenanceNone
Footprint9x9
Required ResearchPower Generation IV
Boost by UnityAvailable
DesignationWater Extraction & Processing Water Extraction & Processing.png
VariantsCooling Tower

The Cooling Tower (Large) is a much higher throughput and physically much larger variant of the Cooling Tower which allows for the conversion of Steam (Super), Steam (High), Steam (Low), and Steam Depleted byproducts into Water. As the ratio of Water to all types of steam is 1:1, the Cooling Tower (Large) thus recovers 75% of the Water contained from Steam (Low), and Steam Depleted. Compared to the regular Cooling Tower, this marks a 50% increase in the Water recovery rate.

It can process the resulting steam output from up to 16 Arc Furnace II machines or 4 Exhaust Scrubbers. Conversely, it takes exactly 3 of these to handle the steam output of a single Nuclear Reactor with 3x output.

Recipes

Below are all the recipes, which this building is capable of producing. Note, that some of them may be locked behind Research, and not immediately available in your game.

16
Steam (High).png
96
10 Clock.png
Transform.png
60 Clock 60s.png
10
Water.png
60
16
Steam (Low).png
96
10 Clock.png
Transform.png
60 Clock 60s.png
12
Water.png
72
16
Steam (Super).png
96
10 Clock.png
Transform.png
60 Clock 60s.png
8
Water.png
48
16
Steam Depleted.png
96
10 Clock.png
Transform.png
60 Clock 60s.png
12
Water.png
72