Difference between revisions of "Cooling Tower (Large)"
Thadius856 (talk | contribs) m (typo) |
m (Rename "Steam Hi" and "Steam Lo" in recipes to "Steam (High)" and "Steam (Low)") |
||
(13 intermediate revisions by 7 users not shown) | |||
Line 2: | Line 2: | ||
| Name = Cooling Tower (Large) | | Name = Cooling Tower (Large) | ||
| Tier = 2 | | Tier = 2 | ||
| Description = Improves [[Water]] efficiency of a power plant by recovering some [[Steam]] back to Water. | | Description = Improves [[Water]] efficiency of a power plant by recovering some [[Steam]] back to Water. | ||
| Recipe = | | Recipe = | ||
Line 15: | Line 14: | ||
| Maintenance = None | | Maintenance = None | ||
| Footprint = 9x9 | | Footprint = 9x9 | ||
| Research = | | BoostByUnity = yes | ||
| Designation = | | Research = Power Generation IV | ||
| Designation = Water Extraction & Processing | |||
| Variants = [[Cooling Tower]] | | Variants = [[Cooling Tower]] | ||
}} | }} | ||
The '''Cooling Tower (Large)''' is a much higher throughput and physically much larger variant of the [[Cooling Tower]] which allows for the conversion of | The '''Cooling Tower (Large)''' is a much higher throughput and physically much larger variant of the [[Cooling Tower]] which allows for the conversion of {{infoicon|Steam (Super)}}, {{infoicon|Steam Hi}}, {{infoicon|Steam Lo}}, and {{infoicon|Steam Depleted}} byproducts into {{infoicon|Water}}. As the ratio of {{infoicon|Water}} to all types of steam is 1:1, the Cooling Tower (Large) thus recovers 75% of the Water contained from {{infoicon|Steam Lo}}, and {{infoicon|Steam Depleted}}. Compared to the regular Cooling Tower, this marks a 50% increase in the Water recovery rate. | ||
It can process the resulting steam output from up to 16 [[Arc Furnace II]] machines or 4 [[Exhaust Scrubber]]s. Conversely, it takes exactly 3 of these to handle the steam output of a single [[Nuclear Reactor]] with 3x output. | |||
{{recipe define | |||
== | | Input1Name = Steam (Super) | ||
{{ | | Input1Qty = 16 | ||
| Input1Name = Steam | | Time = 10 | ||
| Input1Qty = | | Output1Name = Water | ||
| Output1Qty = 8 | |||
}}{{recipe define | |||
| Input1Name = Steam (High) | |||
| Input1Qty = 16 | |||
| Time = 10 | | Time = 10 | ||
| Output1Name = Water | | Output1Name = Water | ||
| Output1Qty = | | Output1Qty = 10 | ||
}} | }}{{recipe define | ||
{{ | | Input1Name = Steam (Low) | ||
| Input1Name = Steam | | Input1Qty = 16 | ||
| Input1Qty = | |||
| Time = 10 | | Time = 10 | ||
| Output1Name = Water | | Output1Name = Water | ||
| Output1Qty = | | Output1Qty = 12 | ||
}} | }}{{recipe define | ||
{{ | |||
| Input1Name = Steam Depleted | | Input1Name = Steam Depleted | ||
| Input1Qty = | | Input1Qty = 16 | ||
| Time = 10 | | Time = 10 | ||
| Output1Name = Water | | Output1Name = Water | ||
| Output1Qty = | | Output1Qty = 12 | ||
}} | }} | ||
{{Footer Infobox}} |
Latest revision as of 15:50, 16 May 2023
Construction | |
Workers | 4 |
Electricity | None |
Maintenance | None |
Footprint | 9x9 |
Required Research | Power Generation IV |
Boost by Unity | Available |
Designation | Water Extraction & Processing |
Variants | Cooling Tower |
The Cooling Tower (Large) is a much higher throughput and physically much larger variant of the Cooling Tower which allows for the conversion of Steam (Super), Steam (High), Steam (Low), and Steam Depleted byproducts into Water. As the ratio of Water to all types of steam is 1:1, the Cooling Tower (Large) thus recovers 75% of the Water contained from Steam (Low), and Steam Depleted. Compared to the regular Cooling Tower, this marks a 50% increase in the Water recovery rate.
It can process the resulting steam output from up to 16 Arc Furnace II machines or 4 Exhaust Scrubbers. Conversely, it takes exactly 3 of these to handle the steam output of a single Nuclear Reactor with 3x output.
Recipes
Below are all the recipes, which this building is capable of producing. Note, that some of them may be locked behind Research, and not immediately available in your game.
This article invokes definition of game's source data (either directly, or with one or several template invokes). Editing it will result in updates to some of the stored tables, which in turn updates automated data lists. See more. If you've found incorrect data, related to this article's topic, it is a good place to start searching for definitions, requiring updates. |
General Machines | |
Water Extraction & Processing | |
Food Production | |
Metallurgy & Smelting | |
Power Production | |
Crude Oil Refining | |
Waste Management | |
Transports | |
Storage |
|
Buildings | |
Buildings (For Vehicles) | |
Housing & Services | |
Cargo Docks |
|
Landmarks | |
Planned or Proposed | |
* Only available in the Supporter Edition |