Difference between revisions of "Data Center"

From Captain of Industry Wiki
Jump to: navigation, search
m (Footer Infobox)
(post-Update 1 page update)
Line 4: Line 4:
| Recipe        =  
| Recipe        =  
   {{Machine Recipe
   {{Machine Recipe
     | Input1Name  = Construction Parts III
     | Input1Name  = Construction Parts IV
     | Input1Qty  = 100
     | Input1Qty  = 180
     | Input2Name  = Electronics II
     | Input2Name  = Electronics III
     | Input2Qty  = 120
     | Input2Qty  = 60
    | Input3Name  = Electronics III
    | Input3Qty  = 20
}}
}}
| Workers      = 6
| Workers      = 6
| Electricity  = 0 - 240 KW
| Electricity  = 0 - 1.92 MW
| Computing    = 0 - +48
| Computing    = 0 - +96
| MaintenanceIII = 4
| MaintenanceIII = 4
| Footprint    = 18x11
| Footprint    = 18x11
| BoostByUnity  = no
| BoostByUnity  = no
| Research      = Computing (research)
| Research      = Datacenter (research)
| Designation  = General Machines
| Designation  = General Machines
| Variants      =  
| Variants      =  
}}
}}
The '''Data Center''' is a machine containing up to 48 server racks. Each server rack is able to provide 1 [[TFlop]]s of [[Computing Power]]. A single server rack consists of 20 {{infoicon|Server|text=Servers|new=yes}} and can be assembled instantly in the Data Center as long as there are enough Servers in the player's storage.
The '''Data Center''' is a machine containing up to 48 server racks. Each server rack is able to provide 2 [[TFlop]]s of [[Computing Power]]. A single server rack consists of 25 {{infoicon|Server|text=Servers|new=yes}} and can be assembled instantly in the Data Center as long as there are enough Servers in the player's storage.


The Data Center requires {{infoicon|Electricity}}, {{infoicon|Chilled Water|new=yes}}, and {{infoicon|Maintenance III|new=yes}}. An amount of them is shown following table and expression.
The Data Center requires {{infoicon|Electricity}}, {{infoicon|Chilled Water|new=yes}}, and {{infoicon|Maintenance III|new=yes}}. An amount of them is shown following table and expression.
Line 35: Line 33:
|  0 ||  0.0 ||  4.0 ||  0
|  0 ||  0.0 ||  4.0 ||  0
|-
|-
|  1 ||  0.6 ||  4.6 ||  5
|  1 ||  0.6 ||  4.6 ||  40
|-
|-
|  2 ||  1.2 ||  5.2 ||  10
|  2 ||  1.2 ||  5.2 ||  80
|-
|-
|  4 ||  2.3 ||  6.3 ||  20
|  4 ||  2.3 ||  6.3 ||  160
|-
|-
|  8 ||  4.1 ||  8.6 ||  40
|  8 ||  4.1 ||  8.6 ||  320
|-
|-
| 12 ||  6.4 || 11.0 ||  60
| 12 ||  6.4 || 11.0 ||  480
|-
|-
| 16 ||  8.2 || 13.3 ||  80
| 16 ||  8.2 || 13.3 ||  640
|-
|-
| 24 || 12.3 || 17.9 || 120
| 24 || 12.3 || 17.9 || 960
|-
|-
| 32 || 16.4 || 22.6 || 160
| 32 || 16.4 || 22.6 || 1280
|-
|-
| 40 || 20.5 || 27.2 || 200
| 40 || 20.5 || 27.2 || 1600
|-
|-
| 48 || 24.0 || 31.8 || 240
| 48 || 24.0 || 31.8 || 1920
|}
|}


Line 60: Line 58:
::α: truncates "0.15 × Number of Server Racks − 0.40" to integer
::α: truncates "0.15 × Number of Server Racks − 0.40" to integer
:{{infoicon|Maintenance III|new=yes}} = (0.58 × Number of Server Racks + 4.0) {{time}}
:{{infoicon|Maintenance III|new=yes}} = (0.58 × Number of Server Racks + 4.0) {{time}}
:{{infoicon|Electricity}} = (5 × Number of Server Racks) KW
:{{infoicon|Electricity}} = (40 × Number of Server Racks) KW


{{Footer Infobox}}
{{Footer Infobox}}

Revision as of 05:27, 10 May 2023

General Machines.png
Data Center
Data Center.png
Datacenter is used to host server racks that you add to it. Each added server rack provides computing as a resource that can be used on your island. Computing is used in advanced machines such as robotic assemblers or microchip makers. It is worth noting that each server rack has its power, cooling, and maintenance demands. However, some people say that all it does is to persist and search in a vast collection of pictures of cats and memes - we were not able to debunk this.
Construction
Construction Parts IV.png
180
+
Electronics III.png
60
WorkersWorker.png 6
ElectricityElectricity.png 0 - 1.92 MW
ComputingComputing.png 0 - +96 TFlops
MaintenanceMaintenance III.png 4.0 / 60 Clock.png
Footprint18x11
Required ResearchDatacenter
Boost by UnityNot Available
DesignationGeneral Machines General Machines.png

The Data Center is a machine containing up to 48 server racks. Each server rack is able to provide 2 TFlops of Computing Power. A single server rack consists of 25 Servers and can be assembled instantly in the Data Center as long as there are enough Servers in the player's storage.

The Data Center requires Electricity, Chilled Water, and Maintenance III. An amount of them is shown following table and expression.

Upkeep cost of Data Center
Server Rack Chilled Water
( / 60 Clock.png )
Maintenance III
( / 60 Clock.png )
Electricity
(KW)
0 0.0 4.0 0
1 0.6 4.6 40
2 1.2 5.2 80
4 2.3 6.3 160
8 4.1 8.6 320
12 6.4 11.0 480
16 8.2 13.3 640
24 12.3 17.9 960
32 16.4 22.6 1280
40 20.5 27.2 1600
48 24.0 31.8 1920

General expression

Chilled Water = (75/128) × (Number of Server Racks − α) / 60 Clock.png
α: truncates "0.15 × Number of Server Racks − 0.40" to integer
Maintenance III = (0.58 × Number of Server Racks + 4.0) / 60 Clock.png
Electricity = (40 × Number of Server Racks) KW