Difference between revisions of "Data Center"
From Captain of Industry Wiki
(Add info of running cost per server) |
|||
Line 20: | Line 20: | ||
| Variants = | | Variants = | ||
}} | }} | ||
The '''Data Center''' is a machine containing up to 48 server racks. Each server rack is able to provide 1 [[TFlop]]s of [[Computing Power]]. The Data Center requires | The '''Data Center''' is a machine containing up to 48 server racks. Each server rack is able to provide 1 [[TFlop]]s of [[Computing Power]]. A single server rack consists of 20 {{infoicon|Server|text=Servers|new=yes}} and can be assembled instantly in the Data Center as long as there are enough Servers in the player's storage. | ||
The Data Center requires {{infoicon|Electricity}}, {{infoicon|Chilled Water|new=yes}}, and {{infoicon|Maintenance III|new=yes}}. An amount of them is shown following table and expression. | |||
{|class="wikitable" style="text-align: right" | |||
|-style="text-align: center" | |||
! {{infoicon|Server|new=yes}} | |||
! {{infoicon|Chilled Water|new=yes}}<br/>({{time}}) | |||
! {{infoicon|Maintenance III|new=yes}}<br/>({{time}}) | |||
! {{infoicon|Electricity}}<br/>(KW) | |||
|- | |||
| 0 || 0.0 || 3.8 || 0 | |||
|- | |||
| 1 || 0.6 || 4.4 || 5 | |||
|- | |||
| 2 || 1.2 || 4.9 || 10 | |||
|- | |||
| 4 || 1.8 || 6.0 || 20 | |||
|- | |||
| 8 || 4.1 || 8.2 || 40 | |||
|- | |||
| 12 || 5.9 || 10.4 || 60 | |||
|- | |||
| 16 || 8.2 || 12.6 || 80 | |||
|- | |||
| 24 || 11.7 || 17.0 || 120 | |||
|- | |||
| 32 || 15.8 || 21.4 || 160 | |||
|- | |||
| 40 || 19.9 || 25.8 || 200 | |||
|- | |||
| 48 || 24.0 || 30.3 || 240 | |||
|} | |||
'''General expression''' | |||
:{{infoicon|Chilled Water|new=yes}} = (75/128) x (Number of Server - α) {{time}} | |||
::α: truncates "0.15 x Number of Server - 0.40" to integer | |||
:{{infoicon|Maintenance III|new=yes}} = (0.55075 x Number of Server + 3.815) {{time}} | |||
:{{infoicon|Electricity}} = (5 x Number of Server) KW | |||
{{Navbox/Machines}} | {{Navbox/Machines}} |
Revision as of 00:15, 18 August 2022
Datacenter is used to host server racks that you add to it. Each added server rack provides computing as a resource that can be used on your island. Computing is used in advanced machines such as robotic assemblers or microchip makers. It is worth noting that each server rack has its power, cooling, and maintenance demands. However, some people say that all it does is to persist and search in a vast collection of pictures of cats and memes - we were not able to debunk this.
Construction | |
Workers | 6 |
Electricity | 0 - 240 KW |
Computing | 0 - +48 TFlops |
Maintenance | 4.0 / 60 |
Footprint | 18x11 |
Required Research | Computing |
Designation | General Machines |
The Data Center is a machine containing up to 48 server racks. Each server rack is able to provide 1 TFlops of Computing Power. A single server rack consists of 20 Servers and can be assembled instantly in the Data Center as long as there are enough Servers in the player's storage.
The Data Center requires Electricity, Chilled Water, and Maintenance III. An amount of them is shown following table and expression.
Server | Chilled Water ( / 60 ) |
Maintenance III ( / 60 ) |
Electricity (KW) |
---|---|---|---|
0 | 0.0 | 3.8 | 0 |
1 | 0.6 | 4.4 | 5 |
2 | 1.2 | 4.9 | 10 |
4 | 1.8 | 6.0 | 20 |
8 | 4.1 | 8.2 | 40 |
12 | 5.9 | 10.4 | 60 |
16 | 8.2 | 12.6 | 80 |
24 | 11.7 | 17.0 | 120 |
32 | 15.8 | 21.4 | 160 |
40 | 19.9 | 25.8 | 200 |
48 | 24.0 | 30.3 | 240 |
General expression
- Chilled Water = (75/128) x (Number of Server - α) / 60
- α: truncates "0.15 x Number of Server - 0.40" to integer
- Maintenance III = (0.55075 x Number of Server + 3.815) / 60
- Electricity = (5 x Number of Server) KW
General Machines | |
Water Extraction & Processing | |
Food Production | |
Metallurgy & Smelting | |
Power Production | |
Crude Oil Refining | |
Waste Management | |
Transports | |
Storage |
|
Buildings | |
Buildings (For Vehicles) | |
Housing & Services | |
Cargo Docks |
|
Landmarks | |
Planned or Proposed | |
* Only available in the Supporter Edition |