Difference between revisions of "Data Center"
From Captain of Industry Wiki
EstebanLB01 (talk | contribs) (requires 3 maintenance III per month, not 4) |
EstebanLB01 (talk | contribs) m (Undo revision 8523 by EstebanLB01 (talk)) Tag: Undo |
||
Line 14: | Line 14: | ||
| Electricity = 0 - 240 KW | | Electricity = 0 - 240 KW | ||
| Computing = 0 - +48 | | Computing = 0 - +48 | ||
| MaintenanceIII = | | MaintenanceIII = 4 | ||
| Footprint = 18x11 | | Footprint = 18x11 | ||
| BoostByUnity = no | | BoostByUnity = no | ||
Line 61: | Line 61: | ||
:{{infoicon|Chilled Water|new=yes}} = (75/128) × (Number of Server Racks − α) {{time}} | :{{infoicon|Chilled Water|new=yes}} = (75/128) × (Number of Server Racks − α) {{time}} | ||
::α: truncates "0.15 × Number of Server Racks − 0.40" to integer | ::α: truncates "0.15 × Number of Server Racks − 0.40" to integer | ||
:{{infoicon|Maintenance III|new=yes}} = (0.58 × Number of Server Racks + | :{{infoicon|Maintenance III|new=yes}} = (0.58 × Number of Server Racks + 4.0) {{time}} | ||
:{{infoicon|Electricity}} = (5 × Number of Server Racks) KW | :{{infoicon|Electricity}} = (5 × Number of Server Racks) KW | ||
{{Navbox/Machines}} | {{Navbox/Machines}} |
Revision as of 16:46, 21 November 2022
Datacenter is used to host server racks that you add to it. Each added server rack provides computing as a resource that can be used on your island. Computing is used in advanced machines such as robotic assemblers or microchip makers. It is worth noting that each server rack has its power, cooling, and maintenance demands. However, some people say that all it does is to persist and search in a vast collection of pictures of cats and memes - we were not able to debunk this.
Construction | |
Workers | 6 |
Electricity | 0 - 240 KW |
Computing | 0 - +48 TFlops |
Maintenance | 4.0 / 60 |
Footprint | 18x11 |
Required Research | Computing |
Boost by Unity | Not Available |
Designation | General Machines |
The Data Center is a machine containing up to 48 server racks. Each server rack is able to provide 1 TFlops of Computing Power. A single server rack consists of 20 Servers and can be assembled instantly in the Data Center as long as there are enough Servers in the player's storage.
The Data Center requires Electricity, Chilled Water, and Maintenance III. An amount of them is shown following table and expression.
Server Rack | Chilled Water ( / 60 ) |
Maintenance III ( / 60 ) |
Electricity (KW) |
---|---|---|---|
0 | 0.0 | 4.0 | 0 |
1 | 0.6 | 4.6 | 5 |
2 | 1.2 | 5.2 | 10 |
4 | 2.3 | 6.3 | 20 |
8 | 4.1 | 8.6 | 40 |
12 | 6.4 | 11.0 | 60 |
16 | 8.2 | 13.3 | 80 |
24 | 12.3 | 17.9 | 120 |
32 | 16.4 | 22.6 | 160 |
40 | 20.5 | 27.2 | 200 |
48 | 24.0 | 31.8 | 240 |
General expression
- Chilled Water = (75/128) × (Number of Server Racks − α) / 60
- α: truncates "0.15 × Number of Server Racks − 0.40" to integer
- Maintenance III = (0.58 × Number of Server Racks + 4.0) / 60
- Electricity = (5 × Number of Server Racks) KW
General Machines | |
Water Extraction & Processing | |
Food Production | |
Metallurgy & Smelting | |
Power Production | |
Crude Oil Refining | |
Waste Management | |
Transports | |
Storage |
|
Buildings | |
Buildings (For Vehicles) | |
Housing & Services | |
Cargo Docks |
|
Landmarks | |
Planned or Proposed | |
* Only available in the Supporter Edition |