Difference between revisions of "Steam Depleted"
(steam dep, hi, lo all lack info about new thermal storage -> outdated) |
|||
(9 intermediate revisions by 4 users not shown) | |||
Line 1: | Line 1: | ||
{{outdated}} | |||
{{Infobox material | {{Infobox material | ||
| Name | | Name = {{PAGENAME}} | ||
| Type1 | | Type1 = Crafted material | ||
| State | | State = Fluid | ||
| | | TrackTransport = no | ||
| StoredIn | | StoredIn = None | ||
| Variants | | Variants = [[Steam (Super)]]<br>[[Steam (Low)]]<br>[[Steam Depleted]] | ||
}} | }} | ||
'''Steam Depleted''' is the lowest energy state of Steam (Highest energy state being | '''Steam Depleted''' is the lowest energy state of Steam (Highest energy state being {{infoicon|Steam Super|new=yes}} and intermediate energy states being {{infoicon|Steam Hi}} and {{infoicon|Steam Lo}}.) | ||
Steam Depleted is produced by consuming the energy of | Steam Depleted is produced by consuming the energy of {{infoicon|Steam Lo}} in a [[Low-pressure Turbine|Low-Pressure Turbine]] to generate {{infoicon|Electricity}}. | ||
Steam Depleted can be consumed in three ways: It turns into | Steam Depleted can be consumed in three ways: It turns into {{infoicon|Water}} and {{infoicon|Brine}} by using it in a [[Thermal Desalinator]] to desalinate {{infoicon|Seawater}} or is condensated into {{infoicon|Water}} in a [[Cooling Tower]] or is released into the atmosphere via a [[Smoke Stack]]. | ||
Steam Depleted is transferred via [[Pipe]] [<nowiki/>[[Pipe II|II]] • [[Pipe III|III]]]. | Steam Depleted is transferred via [[Pipe]] [<nowiki/>[[Pipe II|II]] • [[Pipe III|III]]]. | ||
Although other | Although other (except {{infoicon|Chilled Water|new=yes}}) [[:Category:Fluid products|Fluid Products]] can be stored in a [[Fluid Storage]] [<nowiki/>[[Fluid Storage II|II]] • [[Fluid Storage III|III]] • [[Fluid Storage IV|IV]]], any kind of steam can NOT be stored in a [[Fluid Storage]] [<nowiki/>[[Fluid Storage II|II]] • [[Fluid Storage III|III]] • [[Fluid Storage IV|IV]]]. Currently the best way to store '''Steam''' would be in long pipe sections. | ||
{{Footer Infobox}} | |||
{{ | |||
Latest revision as of 08:30, 9 February 2024
Type | Crafted material |
State | Fluid |
Transported by | Pipe [II•III] |
Stored in | None |
Created in | Boiler (Gas) Hydrogen Reformer Low-Pressure Turbine Low-Pressure Turbine II Thermal Storage |
Used in | Cooling Tower Cooling Tower (Large) Smoke Stack Smoke Stack (Large) Thermal Desalinator |
Variants | Steam (Super) Steam (Low) Steam Depleted |
Steam Depleted is the lowest energy state of Steam (Highest energy state being Steam (Super) and intermediate energy states being Steam (High) and Steam (Low).)
Steam Depleted is produced by consuming the energy of Steam (Low) in a Low-Pressure Turbine to generate Electricity.
Steam Depleted can be consumed in three ways: It turns into Water and Brine by using it in a Thermal Desalinator to desalinate Seawater or is condensated into Water in a Cooling Tower or is released into the atmosphere via a Smoke Stack.
Steam Depleted is transferred via Pipe [II • III].
Although other (except Chilled Water) Fluid Products can be stored in a Fluid Storage [II • III • IV], any kind of steam can NOT be stored in a Fluid Storage [II • III • IV]. Currently the best way to store Steam would be in long pipe sections.
Recipes
Below are all the recipes, which contain this item. Note, that some of them may be locked behind Research, and not immediately available in your game.
Production